In upstream testing, a part is pressurized and the leak rate is determined by measuring what leaks into the part to replace what is leaking out. If the testing requirements are not as rigorous and the pressure requirements are not that high-for example, leak testing a casting at 10 psi-an upstream test will usually suffice.
Downstream leak testing is used for difficult applications that require testing at pressures in excess of 150 psi, short test times, measurement of small leaks, very accurate and repeatable results or precise temperature compensation.
A downstream leak testing system consists of a sealed chamber that encloses all or part of the test item and a second sealed chamber, or reservoir, that has a volume similar to the volume between the test chamber and the test item. Prior to the leak test, the test chamber and reservoir are open to the atmosphere or they can be evacuated to a test vacuum or pressurized to a specific pressure, depending on application requirements. When the leak test is initiated, both volumes are isolated from the chamber pressure source and sealed. The test part is then pressurized to test pressure. Any leakage from the test part flows into the test chamber, causing its pressure to increase. Because the reservoir is still at the initial pressure, part leakage will flow through the mass flow transducer into the test chamber. Output from the mass flow transducer is a direct measure of the leakage of the test part. Because the mass flow transducer is not exposed to the test part pressure, the measurement it provides is independent of pressure.
The downstream method has the advantage of providing faster test times because the volume affecting the leak system response and the related stabilization time required is minimized. The best-in-class mass flow sensors are custom tuned for maximum stability in relevant ranges and, as a result, can accurately measure very small test part leaks.

The downside of downstream testing is the added cost of tooling needed to perform the test. When failsafe leak testing is the goal, the promise of greater accuracy usually makes downstream testing the method of choice. Sometimes the high pressure under which products or components function-and at which they must be leak tested-also mandate that the downstream testing method be used, despite the added costs for downstream test fixturing.
To compensate for this possibility, and to make the testing failsafe, the more accurate systems employ a bias leak, which verifies that the entire system is working and that the test circuit’s integrity is not compromised. A bias leak is simply the introduction of a known leak as a self-check of the testing system. If valves are not operating properly and test seals are insufficient, the bias leak will not measure as a leak, indicating that remedial actions on the test system need to be taken. Ideally, introducing a bias leak should not affect test circuit design and volume.
Updated electronic technology for self-calibration and automatic validation of leak testing can now achieve an accuracy of ±2% of reading or 0.02 sccm, which allows manufacturers to maintain the highest quality standards without slowing production line output for time-consuming mechanical calibration. Unlike mechanical calibration methods, the calibration process is automatic and no operator judgment is required. Because production delays involved with off-line mechanical calibration are eliminated, operators not only achieve higher accuracy but higher production yields, as well.
When using mass flow leak testing, test measurements are created by a decrease in the number of air molecules (the leak) in the test volume and an apparent or virtual leak caused by adiabatic heating or cooling, trapping or part temperature effects.
Typically, the dominant thermal effect in leak testing results when a part is at atmospheric pressure and the ambient temperature is pressurized. The warmer air temperature then cools to the temperature of the part. If a part is at atmosphere and then evacuated, the reverse occurs. Thus, adiabatic heating or cooling must be managed by the test system to achieve reliable results. This is best done with volume fillers that reduce the quantity of air being compressed and the response time of the system by decreasing the distance air molecules travel before reaching the fixture or test part walls.
The rate at which a part reaches ambient temperature is proportional to the difference between the part temperature and the ambient temperature. When a cool part is pressurized, the test air will cool down toward the temperature of the part. As the part temperature rises toward ambient, the test air temperature will rise with the part temperature, increasing the air pressure and creating a virtual leak that will mask the actual leak. Alternately, the reverse occurs if the part is warmer than ambient.
All of these processes are known physical processes that will alter test readings if there is no instrumentation to measure and compensate for virtual leaks masking real leak rates. Unfortunately, many who are less schooled in the underlying mechanisms of leak test requirements still do not manage these temperature effects and, therefore, mistakenly conclude that mass flow leak testing is only viable for gross leak testing applications; in reality, the better mass flow leak testing systems that can compensate for temperature are accurate for leaks as small as 0.05 sccm.
Temperature compensation involves automatically differentiating between the actual leak and the virtual leak comprising the test measurement. Leak testing without automated temperature compensation is always questionable and does not allow for adequate gage repeatability and reproducibility in most applications.

There is significant variation in yields from leak testing-intensive manufacturing operations, from one plant to another. Often, those with lower yields or substandard quality do not understand the real world requirements of test-centric assembly such as temperature compensation methods, using bias leak testing, or the need for electronic inline calibration and validation methods. Enlisting the services of engineers who have a singular focus on leak testing is recommended to create the system capabilities that enable a failsafe leak-testing standard. Q
Jacques Hoffmann is founder and president of InterTech Development Co. (Skokie, IL). For more information, call (847) 679-3377, e-mail info@intertechdevelopment.com or visit www.intertechdevelopment.com.