Eddyfi announced the launch of the Sharck™ fillet weld probe. It is designed around the well-known tangential ECA technology (TECA), which is specifically made for carbon steel crack assessment. Not only does the technology enable establishing crack position and measuring its length, but also its depth, with only minimal surface preparation. Similar to the Sharck butt weld probe, this one can tolerate a liftoff (paint or coating, for example) up to 3 mm (0.120 in).
The Sharck fillet weld probe was specifically designed to make inspecting 90° T-joints easy. The probe combines the ability of individual, spring-loaded fingers to conform to weld crowns with a clever mechanical design enabling parts of the array to be adjusted to the cap angle (30°, 45°, or 60°). The result is a compelling C-scan image for rapid and intuitive analysis.